Here i want to share the customer feedback on Subaru FeeSSM v1.2.5 obd cable.
My experience so far . . .
I hooked up the USB cable to the laptop running Windows 7 system — it
recognized the cable. Then turned on FreeSSM, and went to preferences.
It had already been set to Serial Port COM3.
I then connected the Subaru OBD cable,
turned the ignition on, and selected “Test Diagnostic Interface”. It
failed. I tried again, and it failed again. I shut off the ignition and
closed FreeSSM (which apparently got hung up and stopped responding. It
took some time for it to close down).
The next time, I opened FreeSSM v1.2.5 software,
clicked on Test Diagnostic Interface, and a window popped up asking to
connect the OBD connector and turn the ignition to On, which I did. Then
I clicked “Start” in the little window, and the test was completed
successfully.
FreeSSM logged into the ECM and TCM without a hitch, and found no codes. (It also listed the Cruise Control, and Inhibitor, with a green check mark, at the left side.)
“Adjustments” and “System Tests” etc. all came up… However, when I went
to ECM “Measuring Blocks”, I got the main screen (grid where Blocks are
to be listed) but no list of blocks to select. Took a few moments of
thought and I clicked on the green + sign at the buttom — up popped the
list. Same for the TCM.
So far so good. I didn’t start the engine but selected a few TCM
Measuring Blocks, such as “Pedal Position%”, Line and AWD duty
cycle, wheel speed etc. (When more than one is selected, the up/down
buttons at the bottom come on, and a selected block can be moved up and
down the list.)
With the gear in P or N, the AWD duty cycle was fixed at 5%, but in D
or R was at 30%. This did not change when varying the Pedal Position %,
although the Line duty cycle reading did respond. Not sure why the AWD %
didn’t change, perhaps because the engine was off.
The Measuring Blocks grid can be set to show a combination of
min value, current value and max value. The min and max columns are
selected by toggling the left two (of three) buttons at
the center bottom. I didn’t figure out what the third button does —
looks like max and min, but it didn’t seem to do anything when I clicked
on it — anyone can confirm what it does?
To get the Measuring Blocks to read, the “Start” button at the lower
left is used (same to stop). Till then, there’s just blanks in the grid.
The refresh rate seems to be quite fast — I found
the Pedal Position % reading changing even when I thought I was holding
the pedal steady, and it changed almost “instanteously” when I purposely
moved the pedal.
I’ll get back to it in a short while, when I can take the car out on
the road. In the meantime I wanted to report on the cable’s arrival and
the setup.
http://blog.uobdii.com
Fendt Vario 700 S4 1001 Crossgate Lever Calibration Guide
This instruction show you guide on how to calibrate 1001 Crossgate Lever for Fendt Vario 700 S4 tractor. Related Contents: FENDT Fendias 2...
-
Here I want to share this guide on how to build WIFI connection for Scania VCI-3 V2.21 .And if you have higher version,the method is same.Ho...
-
Cummins CM850 and CM2850 engine fault code 2311,Electronic Fuel Injection Control Valve Circuit - Condition Exists. Fuel pump actuator circu...
-
It is provided for using this function, that the engine is operating in min-/max governor or allspeed-governor mode (f.e. not fixspeed). Ser...