Thursday, November 30, 2023

How to Use SerDia2010 Diagnostic Software Droop Adjustment

It is provided for using this function, that the engine is operating in min-/max governor or allspeed-governor mode (f.e. not fixspeed).


SerDia reads out the actual characteristic lines for Droop and copies both values into the upper chart. Additional the values will be saved.


Related Contents:
Deutz Diagnostic Tool DECOM
2023 Deutz SerDia2010



In parallel the tachometer operates on the right hand.
The actual setpoint value and the actual rotating speed are shown,each as a decimal value below the tachometer and also with indicator and hysteresis region.

Possible interactions:
Button "read data from ECU":
went back to previous value of droop, which was acquired at the start of the UseCase.

Button"store in ECU":
writes all variables for the droop back into the ECU.
If the engine is still running, SerDia will offer to stop the engine automatically,so that the programming of the ECU can take place.

text box "input percentage":
An input into this text box has to be confirmed by ENTER.
After that, SerDia changes all variables for droop and switches over to working page, so all changes will be activated in realtime. 

2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download

The input is limited from 0 to 20 % .
CheckBox "follow droop switch":
If the user want to changes the droop lines autonomous of the droop switch, the checkbox must be deactivated.
After that, the user can change the selector "state of droop switch" manually .
Selector "state of droop switch":

Fendt Vario 700 S4 1001 Crossgate Lever Calibration Guide

This instruction show you guide on how to calibrate 1001 Crossgate Lever for Fendt Vario 700 S4 tractor.   Related Contents: FENDT Fendias 2...