Thursday, January 15, 2026

Deutz DMR3 Engine Controller 82/1074 Engine Brake Flap Actuator Error Solution

82 / 1074 / ExFlCD
Error description:BRAKE FLAP ACTUATOR
Engine brake flap actuator: the current drain measured by ECU is out of the target range or the maximum permissible temperature of the ECU component for power supply of the actuator is  exceeded 

 

Related Contents: 

Deutz DECOM

Deutz Serdia 4.0


 

Error codes
DEUTZ-Errorcode: 82
BlinkCode (short-long-short): 2 - 1 - 9
SPN: 1074
 

Possible FMI:
3: Voltage to high or short circuit to +Ubatt
4: Voltage to low or short circuit to -Ubatt
5: current to low or broken wire
12. Errormode not identifiable
 

Error detection
Errorlamp shows permanent light. Entry in errormemory.
 

Possible reason for error
Engine brake flap actuator: cable break or short circuit, sensor defective, connection cable demaged
 

Take actions for error repair
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it other error properties
System reaction: Warning, shutoff output Behaviour error lamp: permanent light
Selfhealing: no
Signal Priority: 2
Measurement @ errortime: shut off value

Deutz DMR3 Engine Controller 82/1074 Engine Brake Flap Actuator Error Solution

82 / 1074 / ExFlCD Error description:BRAKE FLAP ACTUATOR Engine brake flap actuator: the current drain measured by ECU is out of the target ...