This instruction show you guide on how to solve Deutz EMR3 engine error code 11 SPN107.
Related Contents:
Deutz DECOM Communicator
2023 Deutz SerDia2010
Error description AIR FILTER COND.
Air filter differential pressure: the pressure difference of the intake air between the filter inlet and outlet calculated by ECU is above the target range and the ECU activates a system reaction
Error codes
DEUTZ-Error code: 11
Blink Code (short-long-short): 1 - 3 - 6
SPN: 107
Possible FMI:
0: data valid, but above normal working area
12. Error mode not identifiable
12. Error mode not identifiable
12. Error mode not identifiable
Error Detection
Error lamp shows permanent light. Entry in error memory.
Possible reason for error
Pressure loss above target range with system reaction, air filter clogged or defective, sensor not working, connection cable demaged
Take actions for error repair
Check airfilter and if necessary clean or renew it, check cabling, check air filter and if necessary replace the filter component,check sensor and if necessary replace it, check connection cable
and if necessary repair or replace it other error properties
System reaction: Warning or Warning and power reduction
Behaviour error lamp: permanent light
Selfhealing: yes
Signal Priority: 2
Measurement @ errortime: actual value