This instruction show you guide on how to calibrate 1001 Crossgate Lever for Fendt Vario 700 S4 tractor.
Related Contents:
FENDT Fendias 2024 Diagnostic software
AGCO 2x4 CANUSB
Procedures:
Apply the hand brake
Switch on ignition.
Press to confirm any existing errors displayed in the instrument cluster
Press to display the first main menu level
Press until symbol A flashes
Press to display the second main menu level
Press until symbol A flashes
Press to display the auxiliary spool valve menu level
Press until symbol A flashes
Press to be able to enter the calibration code
Press and enter code 1001
Confirm with
Release crossgate lever → it centers automatically
Confirm with
Push and hold the crossgate lever fully right (with the spring)
Confirm with
Push and hold the crossgate lever fully left (with the spring)
Confirm with
Push and hold the crossgate lever fully forwards (with the spring)
Confirm with
Push and hold the crossgate lever fully backwards (with the spring)
Confirm with
Push and hold the crossgate lever fully right (with the spring)
In this position, push and hold the crossgate lever fully forwards (with the spring)
Confirm with
Push and hold the crossgate lever fully right (with the spring)
In this position, push and hold the crossgate lever fully backwards (with the spring)
Confirm with
Push and hold the crossgate lever fully left (with the spring)
In this position, push and hold the crossgate lever fully backwards (with the spring)
Confirm with
Push and hold the crossgate lever fully left (with the spring)
In this position, push and hold the crossgate lever fully forwards (with the spring)
Confirm with
Push and hold the crossgate lever fully right (not with the spring)
Confirm with
Push and hold the crossgate lever fully left (not with the spring)
Confirm with
Push and hold the crossgate lever fully forwards (not with the spring)
Confirm with
Push and hold the crossgate lever fully backwards (not with the spring)
Confirm with
If calibration is error-free, OK appears and the calibration values are stored
Note:
The values are not applied until after a key reset.
Wait at least 60 seconds before switching the ignition ON.
If incorrect values are detected or the conditions were not met, ERROR appears
1001 Calibration code
FXX Fault code