Thursday, May 21, 2026

How to Solve Deutz EMR3 90 / 94 / FlPSCD Fuel Pressure Error

Here is instruction show you guide on how to solve Deutz engine EMR3 controller module 90 / 94 / FlPSCD Error FUEL PRE PRESS.



Related Contents: 
Deutz DECOM

Deutz Serdia 4.0
Low fuel pressure sensor: the voltage of sensor measured by
ECU is out of the target range


Error codes
DEUTZ-Errorcode: 90
BlinkCode (short-long-short): 2 - 1 - 6
SPN: 94


Possible FMI:
3: Voltage to high or short circuit to +Ubatt
4: Voltage to low or short circuit to -Ubatt
12. Errormode not identifiable
12. Errormode not identifiable


Error detection
Errorlamp shows permanent light. Entry in errormemory.


Possible reason for error
cable break or short circuit, sensor defective, connection cable demaged


Take actions for error repair
Check cabling, if sensor not working, check sensor and if
necessary replace it, check connection cable and if necessary repair or replace it other error properties
System reaction: Warning, substitute value
Behaviour error lamp: permanent light
Selfhealing: yes
Signal Priority: 3

How to Solve Deutz EMR3 90 / 94 / FlPSCD Fuel Pressure Error

Here is instruction show you guide on how to solve Deutz engine EMR3 controller module 90 / 94 / FlPSCD Error FUEL PRE PRESS. Related Conte...